显微摄像中的黑边现象分析(英文)
时间:2009-06-22 17:39:54        点击数:260

Peripheral darkening (vignetting) in microscopy and macroscopy photography

Vignetting in micro or macrophotography is peripheral darkening at the edge of the image. This effect can be either desirable or undesirable depending on the field of application.

Vignetting is categorised according to different degrees of severity:

             
weak              moderate           severe

In addition, the symmetry of the vignetting is also judged. An asymmetrical appearance to the vignetting ring is the first indicator that the optical system is not correctly centred. Mostly the camera unit is not positioned perfectly over the microscope’s optical axis. In rare cases, the camera's sensor chip is not correctly positioned inside the camera body.In normal photography, these production tolerances mostly go unnoticed. However, when used in conjunction with a microscope, all mechanical irregularities and image distortions in the parallel light path are very much intensified.

Centric and non-centric position of the vignetting ring: 
                    

                      centric position                  non-centric position

Workaround: If it is not possible to adjust the optical system so that it is precisely centred, then with cameras with in-built zoom lenses it is possible to zoom in to the image until the vignetting and misalignment disappear. The image quality is not disadvantaged by this approach, as in the process any image section within the vignetting is enlarged to a full format image.

Depending on the field of application, vignetting may be acceptable. In the case of gastroscopic or endoscopic photography in medical use, 100% of the round image must be reproduced on the rectangular camera sensor. The doctor needs to view 100% of the information on the image transmitted through the fibre optics, and will therefore accept vignetting and blurring around the edges of the ring.

In microscopy, more importance is placed on achieving a full format, rectangular reproduction of the field of view than on achieving a circular reproduction of the field of view that is true to the original. The camera sensor should be illuminated in such a way that there is no possibility of vignetting. With this optical adjustment, the camera’s pixel count can be utilised to the optimum.

What actually causes vignetting?

The majority of optical elements such as lens elements, apertures, tubes and lens units are manufactured as round elements. Only the camera sensor is made as a rectangular electronic component. Vignetting is therefore the reproduction of the optical edge of the microscope’s light path. By reproducing the round microscope image on the rectangular camera sensor, all of the areas of the image lying outside of the round microscope image remain unlit and thus black.

Only with greater magnification of the round microscope image is the rectangular camera sensor exposed to light in such a way that the image is illuminated over the entire sensor area without peripheral darkening (vignetting).

If high image quality is important to you, then optical adjustment between the microscope and the camera is indispensable. The LM digital adapter ensures that the image is projected onto the camera chip at the optimum size. Furthermore, the microscope’s chromatic image distortions must be compensated for. As a result of the interaction between the optical limit and the light, there are considerably more serious image distortions on the edges than in the middle of the optical axis. If the adapter does not fulfil its function to the optimum, then there will be flaws in the reproduction (chromatic and spherical aberrations) and vignetting. An optimum adjustment between the microscope and the camera is only possible if the camera’s lens can be removed.
The camera lens unit with its many optical elements (up to 19 lens elements and more in the case of zoom lens units) only has the effect of reducing quality in the microscopic light path and is not needed in microphotography. For this reason, digital SLR cameras and professional camcorders are equipped with interchangeable lens mountings.
In this case, the microscope adapter is directly connected to the camera body via the bayonet mount.

The most common causes of vignetting in microphotography and macrophotography:
•Optical axis of camera and microscope not in line
•Camera lens limits the light path
•No optical adjustment between the microscope and the camera
•An unsuitable projection lens is already integrated in the microscope’s photo tube or C-mount connection
•The optical system is off-centre

本文来源于:http://www.lmscope.com/produkt22/FAQ_52_en.shtml

相关链接:显微摄像中的黑边现象分析(中文)

打印】【关闭窗口
 
上一页:什么是GFP? 下一页:显微镜摄像头与数码相机谁更适合显微照相?
产品推荐:
数码显微镜 专业数码成像产品 偏光显微镜 显微镜接口 奥林巴斯显微镜 金相显微镜 900万像素MD90 500万像素MD50 300万像素MD30
销售区域: 广州 深圳 珠海 中山 佛山 东莞 肇庆 汕头 湖南 湖北 江苏 广东 广西 新疆 四川 山东 北京 杭州 温州 武汉 长沙 南京 大连 长春 西安 内蒙古 青海 甘肃
友情链接:
监控摄像机
奥林巴斯
新浪博客
百度博客
google
百度搜索
网易博客
东南科仪

版权所有 2009 (C) 广州明美科技有限公司 All Rights Reserved.
粤ICP备06070121